    Foam Skin Insulated & LAP Sheathed Jelly Filled Cables to IEC60708

    Quantity Order:
    Origin:
    Hong Kong SAR

    Specification :

    Application

    The cables are designed for use in access or trunk networks, from telephone exchange to subscriber area. The cables are suitable for installation in ducts, direct burial in the ground and also for aerial installation with integral suspension strand.Jelly filled option is for subscriber’ s cables installed underground or along the edge of pavement. An armoured option is offered for direct burial installations. A figure-8 self support option is offered for aerial installation.

    Standards

    • IEC 60708

    Construction

    Conductors
    Solid annealed bare copper, 0.4/ 0.5/ 0.6/ 0.63/ 0.8/ 0.9 mm as per class 1 of IEC 60228 & ASTM B-3

    Insulation
    Foam Skin which is a composite polyethylene insulation made of an inner cellular layer and an outer solid skin, as per IEC 60708/ BS EN 50290-2-23/ BS 6234/ ASTM D 1248/ NFC 32-060/ VDE 0207

    Twisted Pairs
    Insulated conductors are twisted into pairs with varying lay length to minimize crosstalk

    Cabling Element
    Twisted Pairs

    Cable Core Assembly
    Cables with 100 pairs or less are composed of 10-pair sub-units; cables with over 100 pairs are composed of 50 or 100-pair units. Any extra pairs form a separate unit. Units are identified by colour coded binders. Standard construction is per IEC 60708 given in Cable Make Up Diagram

    Core Wrapping
    One or more non-hygroscopic polyester tapes are helically or longitudinally laid with an overlap. These tapes furnish thermal, mechanical as well as high dielectric protection between shielding and individual conductors

    Moisture Barrier
    A layer of aluminium tape ( 0.15mm) coated with PE-copolymer on one or both sides is applied longitudinally with overlap over the cable core to provide 100% electrical shielding coverage and ensure a barrier against water vapor. In cables with more than 200 pairs, the aluminum tape may be corrugated for improved cable flexibility

    Filling ( optional)
    The cable core interstices are filled with petroleum jelly to avoid longitudinal water penetration within the cable. The water resistant filling compound is applied to the air space between non-hygroscopic tape and shield, shield and sheath within the cable core

    Sheath
    Black low density polyethylene as per BS 6234/ IEC 60708/ ASTM D 1248, being able to withstand exposure to sunlight, temperature variations, ground chemicals and other environmental contaminants

    Ripcord
    Ripcord may be provided for slitting the sheath longitudinally to facilitate its removal

    Spare Pairs ( optional)
    Spare pairs may be incorporated for 200 and larger pair cables

    Continuity Wire ( optional)
    One tinned copper drain wire may be longitudinally laid to ensure electrical continuity of the screen

    Optional Construction

    Armoured Cable
    Steel wire armour or corrugated steel tape armour is applied over an optional inner polyethylene sheath. For steel tape version, the 0.2/ 0.5mm thick steel tape is coated with a copolymer and applied with an overlap. An outer polyethylene sheath is applied over the armour

    Self-Support Cables
    A 7-strand galvanized steel strand is used as support wire. Black polyethylene sheath covers both core and support wire in a figure-8 construction