DTG-E6 with light weight, small size, and short start time, can be used in higher operating temperature, what now has been used in short-range missile strapdown attitude system, Oil drilling inclinometer tool and other products. Can be used in all kinds of strapdowm attitude system and the inertial measurement instrument with a higher operating temperature requirement. N0. Item Specification 1 Performance Parameter Random Drift ( 1Ã ) d0.2° / h Drift Stability ( 1Ã ) d0.3° / h g-independent d15° / h g-dependent d8° / h Frequency Response e70Hz 2 Technological parameter Power Supply( Three Phase) 205 Hz 10V Power Supply( Single Phase) 8 KHz 7 V Synchronous Speed 6, 015 Synchronizing Time d10 S Output Gradient 7~ 10 mv/ ’ Master torquer 19± 3 © Vice control torquer 2± 0.5 © 3 Torquer scale factor Master torquer e680 ° / h/ mA Vice control torquer e10 ° / h/ mA 4 Max.Tracking Speed e100 ° / s 5 Output Nonlinearity d0.5% 6 Life Time e5000 7 Operating Temperature -20^ + 120 8 Shock Overload( 8ms) e60 g 9 Physical Parameter Dimension ¦ 35.4× 78 mm Mounting flanges 38× 38mm Weight d380 g